EC Error Detection Issues Guide
This issues guide documents the logic that Forerunner uses to surface issues with our Elevation Certificate (EC) Error Detection feature. The table is divided into Elevation Certificate sections and columns are defined as follows:
- EC Field: The Elevation Certificate field that the issue is associated with.
- Issue Trigger: The trigger used to signal an issue flag.
- Type: The Type of Issue. Warnings are typically informational while Errors are potential errors in the completion of the EC.
- Issue Note: The text that you see when an issue is triggered, describing the issue.
Note: Forerunner's Issues feature provides supplementary EC review and should not fully replace your compliance-checking process. Here are a few items that should be checked manually:
- Accuracy of Latitude & Longitude coordinates
- Inclusion of at least 2 photographs
- Correct Diagram Number selection
- Accuracy of CBRS & OPA determination
- Accuracy of FIRM Index Date
- Presence of surveyor, engineer, or architect stamp & signature
- Accuracy of Sections E, F, G
- Attachment of Flood Openings Certification, where applicable
- Attachment of V Zone Certification, where applicable
- Amendments made using a Memo of Correction
- Presence of breakaway walls
While Forerunner does not warrant any of the issues flagged by our EC Error Detection feature, we strive to be as accurate and transparent as possible in its development. If you have any questions, or if you have a suggested addition to this list, please don't hesitate to reach out to us at support@withforerunner.com.
Section A
EC Field | Issue Trigger | Type | Issue Note |
A1. Building Owners Name | Building Owners Name does not have a value or is labeled "NA" | Warning | "This field should not be empty." |
A2. Building Street Address | Building Street Address does not have a value or is labeled "NA" and there is no value entered in A3. Property Description. | Error | "Either A2 or A3 must be filled out" |
A2. Building Street Address [City] | City does not have a value or is labeled "NA" | Error | "This field should not be empty." |
A2. Building Street Address [State] | State does not have a value or is labeled "NA" | Error | "This field should not be empty." |
A2. Building Street Address [Zip] | Zip does not have a value or is labeled "NA" | Error | "This field should not be empty." |
A3. Property Description | Building Street Address does not have a value or is labeled "NA" and there is no value entered in A2. Building Street Address | Error | "Either A2 or A3 must be filled out" |
A4. Building Use | Building Use does not have a value or is labeled "NA" | Error | "This field should not be empty." |
A5. Latitude/Longitude | Latitude/Longitude does not have a value or is labeled "NA" | Warning | "This field should not be empty." |
A5. Latitude/Longitude | Latitude/Longitude does not have a value or is labeled NA | Error | "Latitude/Longitude cannot be empty" |
A5. Latitude/Longitude |
Latitude/Longitude Datum does not have a value | Error | "Latitude/Longitude Datum cannot be empty" |
A7. Building Diagram Number | Building Diagram Number does not have a value or is labeled "NA" | Error | "This field should not be empty." |
A7. Building Diagram Number | Building Diagram Number is any value other than 1A, 1B, 2A, 2B, 3, 4, 5, 6, 7, 8, 9 | Error | "The value entered is not a valid result" |
A7. Building Diagram Number | The Building Diagram Number field has more than 1 value | Error | "There should only be one value for this field." |
A7. Building Diagram Number | Building Diagram Number is 5, 6, 7, or 8 and there is also a value in C2.d | Error | "All areas below elevated floors are considered enclosures and not attached garages, therefore there should not be a value in C2.d Attached garage." |
A7. Building Diagram Number | Building Diagram Number is 1a,1b or 5 but A8.a has a value | Error | "The Building Diagram type indicates that the building should not have an enclosure, however there is a value entered in A8.a Square footage of crawlspace or enclosure." |
A7. Building Diagram Number | Building Diagram Number is 6,7,8 or 9 but A8.a has no value | Error | "The Building Diagram type indicates that the building should have an enclosure, however there is no value entered in A8.a Square footage of crawlspace or enclosure." |
A7. Building Diagram Number | Building Diagram Number is 5, 6, 7, or 8 and there is also a value in A9.a | Error | "All areas below elevated floors are considered enclosures and not attached garages, therefore there should not be a value in A9.a Square footage of attached garage." |
A8.a Square footage of crawlspace or enclosure(s) | Square footage of crawlspace or enclosure(s) is empty | Warning | "This field should not be empty, instead "N/A" should be used if there is no value." |
A8.b Number of permanent flood openings in the crawlspace or enclosure(s) | Number of permanent flood openings in the crawlspace or enclosure(s) is empty | Warning | "This field should not be empty, instead "N/A" should be used if there is no value." |
A8.b Number of permanent flood openings in the crawlspace or enclosure(s) | The Regulatory Flood Zone is A, A1-20, AE, V, V1-20, VE, AH and the Building Diagram number is 6,7,8 or 9, and there is a non-zero, non-null value in A8.a, and there are less than 2 permanent flood openings (A8.b) | Error | "All elevated structures in the SFHA with enclosures must have a minimum of two openings." |
A8.c Total net area of flood openings | Total net area of flood openings is empty | Warning | "This field should not be empty, instead "N/A" should be used if there is no value." |
A8.c Total net area of flood openings | There are non-zero, non-null values in A8.a & A8.b and Net area of flood openings value (A8.c) is smaller than Square footage of crawlspace or enclosure(s) (A8.a) | Error | "The flood openings do not meet NFIP minimum criteria because the total net area of flood openings is smaller than the Square footage of crawlspace or enclosure(s)." |
A8.d Engineered floodvent openings | Always trigger if "Yes" is selected | Warning | "The certificate indicates that there are Engineered floodvent openings. Please manually confirm that there is an accompanying certification by a registered design professional or a copy of the ICC Evaluation Service report." |
A8.d Engineered floodvent openings | If there is an non-zero numeric value in number of permanent flood openings (A8.b), then Engineered floodvent openings (A8.d) must be filled out | Error | "There are permanent flood openings present in the crawlspace or enclosure so this field should not be empty." |
A9.a Square footage of attached garage | Square footage of attached garage is empty | Warning | "This field should not be empty, instead "N/A" should be used if there is no value." |
A9.b Number of permanent flood openings in the attached garage | Number of permanent flood openings in the crawlspace or enclosure(s) is empty | Warning | "This field should not be empty, instead "N/A" should be used if there is no value." |
A9.c Total net area of flood openings | Total net area of flood openings is empty | Warning | "This field should not be empty, instead "N/A" should be used if there is no value." |
A9.c Total net area of flood openings | There are non-zero, non-null values in A9.a & A9.b and Net area of flood openings value (A9.c) is smaller than the Square footage of attached garage (A9.a) | Error | "The flood openings do not meet NFIP minimum criteria because the total net area of flood openings is smaller than the Square footage of attached garage." |
A9.d Engineered floodvent openings | Always trigger if "Yes" is selected | Warning | "The certificate indicates that there are Engineered floodvent openings. Please manually confirm that there is an accompanying certification by a registered design professional or a copy of the ICC Evaluation Service report." |
A9.d Engineered floodvent openings | If there is an non-zero numeric value in number of permanent flood openings (A9.b), then Engineered floodvent openings (A9.d) must be filled out | Error | "Because there are permanent flood openings present in the attached garage so this field should not be empty." |
Section B
EC Field | Issue Trigger | Type | Issue Note |
B1. NFIP Community Name | NFIP Community Name does not have a value or is labeled "NA" | Error | "This field should not be empty." |
B1. NFIP Community Name | NFIP Community Name does not match the value we get back from FEMA's API | Error | "The value on the EC does not match the Community Name returned by FEMA for this parcel." |
B1. NFIP Community Name | We don't have a NFIP Community Name value for property | Warning | "We are unable to independently verify that this value is correct. Please manually confirm that this field is accurate." |
B1. Community Number | Community Number does not have a value or is labeled "NA" | Error | "This field should not be empty." |
B1. Community Number | Community Number does not match the value we get back from FEMA's API | Error | "The value on the EC does not match the Community Number returned by FEMA for this parcel." |
B1. Community Number | We don't have a Community Number value for property | Warning | "We are unable to independently verify that this value is correct. Please manually confirm that this field is accurate." |
B2. County Name | County Name does not have a value or is labeled "NA" | Error | "This field should not be empty." |
B2. County Name | County Name is not "NA" and does not match the value we get back from FEMA's API | Error | "The value on the EC does not match the County Name returned by FEMA for this parcel." |
B2. County Name | We don't have a County Name value for property | Warning | "We are unable to independently verify that this value is correct. Please manually confirm that this field is accurate." |
B3. State | State does not have a value or is labeled "NA" | Error | "This field should not be empty." |
B3. State | State is not "NA" and does not match the value we get back from FEMA's API | Error | "The value on the EC does not match the State returned by FEMA for this parcel." |
B3. State | We don't have a State value for property | Warning | "We are unable to independently verify that this value is correct. Please manually confirm that this field is accurate." |
B4. Map/Panel Number | Map/Panel Number does not have a value or is labeled "NA" | Error | "This field should not be empty." |
B4. Map/Panel Number | Map/Panel Number does not match the value we get back from FEMA's API | Error | "The value on the EC does not match the Map/Panel Number returned by FEMA for this parcel." |
B4. Map/Panel Number | Map/Panel Number does not match the value we get back from FEMA's API | Error | "The value on the EC does not match the Map/Panel Number returned by FEMA for this parcel." |
B4. Map/Panel Number | We don't have a Map/Panel Number value for property | Warning | "We are unable to independently verify that this value is correct. Please manually confirm that this field is accurate." |
B5. Suffix | Suffix does not have a value or is labeled "NA" | Error | "This field should not be empty." |
B5. Suffix | Suffix does not match the value we get back from FEMA's API | Error | "The value on the EC does not match the Suffix returned by FEMA for this parcel." |
B5. Suffix | Suffix does not match the value we get back from FEMA's API | Error | "The value on the EC does not match the Suffix returned by FEMA for this parcel." |
B5. Suffix | We don't have a Suffix value for property | Warning | "We are unable to independently verify that this value is correct. Please manually confirm that this field is accurate." |
B6. FIRM Index Date | FIRM Index Date does not have a value or is labeled "NA" | Error | "This field should not be empty." |
B7. FIRM Panel Effective/Revised Date | FIRM Panel Effective/Revised Date does not have a value or is labeled "NA" | Error | "This field should not be empty." |
B7. FIRM Panel Effective/Revised Date | FIRM Panel Effective/Revised Date does not match the value we get back from FEMA's API | Error | "The value on the EC does not match the FIRM Panel Effective/Revised Date returned by FEMA for this parcel." |
B7. FIRM Panel Effective/Revised Date | FIRM Panel Effective/Revised Date does not match the value we get back from FEMA's API | Error | "The value on the EC does not match the FIRM Panel Effective/Revised Date returned by FEMA for this parcel." |
B7. FIRM Panel Effective/Revised Date | We don't have a FIRM Panel Effective/Revised Date value for property | Warning | "We are unable to independently verify that this value is correct. Please manually confirm that this field is accurate." |
B8. Flood Zone(s) | Flood Zone(s) does not have a value or is labeled "NA" | Error | "This field should not be empty." |
B8. Flood Zone(s) | Flood Zone(s) does not match the value we get back from FEMA's API | Error | "This value does not match the Flood Zone returned by FEMA for this parcel." |
B8. Flood Zone(s) | Flood Zone(s) does not match the value we get back from FEMA's API | Error | "This value does not match the Flood Zone returned by FEMA for this parcel." |
B8. Flood Zone(s) | There are multiple Flood Zone(s) | Warning | "There are multiple Flood Zones indicated. Please manually verify that the values apply to the structure (not the parcel)." |
B8. Flood Zone(s) | If the Flood zone is AO or A (without a BFE value) let user know that they need to manually check Section E | Warning | "The Building's Flood Zone indicates that Section E should be filled out. Please manually confirm that this section is correct." |
B8. Flood Zone(s) | If the Flood zone is VE or V let user know that they need to also have a V-Zone design certificate | Warning | "The Building's Flood Zone indicates that a V-Zone design certificate should also be present. Please manually confirm that you have also collected this document." |
B8. Flood Zone(s) | We don't have a Flood Zone(s) value for property | Warning | "We are unable to independently verify that this value is correct. Please manually confirm that this field is accurate." |
B9. Base Flood Elevation | Most restrictive Flood Zone is AE, AO, V, or VE and Base Flood Elevation does not have a value or is labeled "NA". | Error | "Given the flood zone determination, this building must also have a BFE value." |
B9. Base Flood Elevation | Most restrictive Flood Zone is A, X, B, or C and Base Flood Elevation does not have a value. Note: "N/A" is acceptable in this case. | Error | "This field should not be empty, instead "N/A" should be used if there is no value." |
B9. Base Flood Elevation | There are multiple BFE(s) | Warning | "There are multiple BFEs indicated. Please manually verify that the values apply to the structure (not the parcel)." |
B9. Base Flood Elevation | EC BFE value is not the same as as FEMA's BFE value | Error | "This value does not match the BFE returned by FEMA for this parcel." |
B9. Base Flood Elevation | EC BFE value is not the same as as FEMA's BFE value | Error | "This value does not match the BFE returned by FEMA for this parcel." |
B9. Base Flood Elevation | We don't have a BFE value for property | Warning | "We are unable to independently verify that this value is correct. Please manually confirm that this field is accurate." |
B10. Source of the Base Flood Elevation | B9. Base Flood Elevation has a value and Source of the Base Flood Elevation does not have a value | Error | "Because B9. Base Flood Elevation has a value, this field should not be empty." |
B10. Source of the Base Flood Elevation | If "Other/Source" is selected | Warning | "Please manually confirm that Other/Source is described." |
B11. Indicate elevation datum used for BFE | B9. Base Flood Elevation has a value and BFE Datum does not have a value | Error | "This field should not be empty." |
B11. Indicate elevation datum used for BFE | BFE Datum value is not the same as FEMA's BFE Datum value | Error | "This value does not match the BFE Datum returned by FEMA for this parcel." |
B11. Indicate elevation datum used for BFE | If "Other/Source" is selected | Warning | "Please manually confirm that Other/Source is described." |
B11. Indicate elevation datum used for BFE | We don't have a BFE Datum value for property | Warning | "We are unable to independently verify that this value is correct. Please manually confirm that this field is accurate." |
B12. Is the building located in a Coastal Barrier Resources System (CBRS) area | CBRS does not have a value | Error | "This field should not be empty." |
B12. Is the building located in a Coastal Barrier Resources System (CBRS) area | We don't have a CBRS value for property | Warning | "We are unable to independently verify that this value is correct. Please manually confirm that this field is accurate." |
B12. Is the building located in a Coastal Barrier Resources System (CBRS) area | CBRS value is not the same as our internal CBRS determination | Error | "This value does not match the Coastal Barrier Resources System returned by the U.S. Fish and Wildlife Service for this parcel." |
B12. Is the building located in a Coastal Barrier Resources System (CBRS) area | CBRS value is not the same as our internal CBRS determination | Error | "This value does not match the Coastal Barrier Resources System returned by the U.S. Fish and Wildlife Service for this parcel. Note: this property is interesected by multiple zones. Please confirm that the CBRS determination on your map is correct." |
Section C
EC Field | Issue Trigger | Type | EC Note |
C1. Building elevations based upon | Building elevations based upon does not have a value | Error | "This field should not be empty." |
C2. Elevation Datum | Elevation Datum does not have a value | Error | "This field should not be empty." |
C2. Elevation Datum | Elevation Datum is not the same as BFE datum | Error | "The Elevation Datum should be the same as the BFE Datum. Note: If there is a conversion explanation in the comments, this discrepancy may be ok." |
C2. Benchmark Utilized | Benchmark Utilized does not have a value | Error | "This field should not be empty." |
C2.a Top of bottom floor | Top of bottom floor does not have a value or is labeled "NA" | Error | "This field should not be empty." |
C2.a Top of bottom floor | Top of bottom floor is higher than Top of next higher floor | Error | "Top of bottom floor should always be a lower elevation than Top of the next higher floor." |
C2.b Top of the next higher floor | Top of the next higher floor does not have a value | Error | "This field should not be empty, instead "N/A" should be used if there is no value." |
C2.c Bottom of the lowest horizontal structural member | Bottom of the lowest horizontal structural member does not have a value | Error | "This field should not be empty, instead "N/A" should be used if there is no value." |
C2.c Bottom of the lowest horizontal structural member | Flood zone value is V or VE, but Bottom of the lowest horizontal structural member does not have a value | Error | "Because the building is in Flood Zone V or VE, an elevation value is required for this field." |
C2.c Bottom of the lowest horizontal structural member | Flood zone value is V or VE, but Bottom of the lowest horizontal structural member does not have a value | Error | "Because the building is in Flood Zone V or VE, an elevation value is required for this field. Note: this property is interesected by multiple zones. Please confirm that the BFE determination on your map is correct." |
C2.d Attached garage | Attached garage does not have a value | Error | "This field should not be empty, instead "N/A" should be used if there is no value." |
C2.d Attached garage | A9.a, A9.b, A9.c, or A9.d has a value, but C2.d does not have a value or is labeled "NA" | Error | "Because there are values in the A9 field, Attached garage should have an elevaton measurement and not be left empty." |
C2.e Lowest elevation of machinery or equipment | Lowest elevation of machinery or equipment does not have a value or is labeled "NA" | Warning | "C2.e should always be filled out, unless it’s a type of building that does not have any machinery/equipment(M/E) servicing the building, like agriculture sheds, self-storage units, cold storage warehouses, etc." |
C2.f Lowest adjacent grade | Lowest adjacent grade does not have a value or is labeled "NA" | Error | "This field should not be empty." |
C2.f Lowest adjacent grade | Lowest adjacent grade is higher than Highest adjacent grade | Error | "Lowest adjacent grade should always have a lower elevation than Highest adjacent grade." |
C2.g Highest adjacent grade | Highest adjacent grade does not have a value or is labeled "NA" | Error | "This field should not be empty." |
C2.h Lowest adjacent grade at lowest elevation of deck or stairs | Lowest adjacent grade at lowest elevation of deck or stairs does not have a value | Error | "This field should not be empty, instead "N/A" should be used if there is no value." |
Section D
EC Field | Issue Trigger | Type | Issue Note |
D2. Certifier’s Name | Certifier's Name does not have a value | Error | "This field should not be empty." |
D3. License Number | License Number does not have a value | Error | "This field should not be empty." |
D11. Date | Date does not have a value | Error | "This field should not be empty." |
D11. Date | Issue Date is after our Certificate Creation Date | Error | "The Issue Date is after the date the Certificate was uploaded to Forerunner." |
C2 Values + Building Diagram
EC Field | Issue Trigger | Type | Issue Note |
A7. Building Diagram Number | Diagram # is 1A, Top of Bottom Floor (c2a) is below Lowest Adjacent Grade (c2f) | Error | "The Building Diagram type indicates that the structure should be slab-on-grade with the bottom floor at or above ground level, however the provided building elevations don't support that. Please double check that A7, C2.A and C2.F are all correct." |
A7. Building Diagram Number | Diagram # is 1A, there are values for c2a + c2b, and Top of Next Highest Floor (c2b) is less than 5.0' above Top of Bottom Floor (c2a) | Error | "The Building Diagram type indicates that the Top of Next Highest Floor should be greater than 5.0' above Top of Bottom Floor, however the provided building elevations don't support that. Please double check that A7, C2.A and C2.B are all correct." |
A7. Building Diagram Number | Diagram # is 1A, Top of Bottom Floor (c2a) is more than 1.0' above Highest Adjacent Grade (c2g) | Warning | "The structure's Top of Bottom Floor is more than 1.0' above the Lowest Adjacent Grade, which is high for a slab-on-grade foundation. Please double check that A7, C2.A and C2.F are all correct." |
A7. Building Diagram Number | Diagram # is 1B, Top of Bottom Floor (c2a) is below or equal to Lowest Adjacent Grade (c2f) | Error | "The Building Diagram type indicates that the structure should be a raised-slab-on-grade with the bottom floor above ground level, however the provided building elevations don't support that. Please double check that A7, C2.A and C2.F are all correct." |
A7. Building Diagram Number | Diagram # is 1B, there are values for c2a + c2b, and Top of Next Highest Floor (c2b) is less than 5.0' above Top of Bottom Floor (c2a) | Error | "The Building Diagram type indicates that the Top of Next Highest Floor should be greater than 5.0' above Top of Bottom Floor, however the provided building elevations don't support that. Please double check that A7, C2.A and C2.B are all correct." |
A7. Building Diagram Number | Diagram # is 1B, Top of Bottom Floor (c2a) is more than 3.0' above Lowest Adjacent Grade (c2f) | Warning | "The structure's Top of Bottom Floor is more than 3.0' above the Lowest Adjacent Grade, which is high for a raised-slab-on-grade foundation. Please double check that A7, C2.A and C2.F are all correct." |
A7. Building Diagram Number | Diagram # is 2A, Top of Bottom Floor (c2a) is above or equal to Lowest Adjacent Grade (c2f) | Error | "The Building Diagram type indicates that the structure should have a basement with the bottom floor below ground level, however the building elevations don't support that. Please double check that A7, C2.A and C2.F are all correct." |
A7. Building Diagram Number | Diagram # is 2A, there are values for c2a + c2b, and Top of Next Highest Floor (c2b) is less than 5.0' above Top of Bottom Floor (c2a) | Error | "The Building Diagram type indicates that the Top of Next Highest Floor should be greater than 5.0' above Top of Bottom Floor, however the provided building elevations don't support that. Please double check that A7, C2.A and C2.B are all correct." |
A7. Building Diagram Number | Diagram # is 2A, Top of Bottom Floor (c2a) is more than 7.0' above Lowest Adjacent Grade (c2f) | Warning | "The Building Diagram type indicates that the structure's Top of Bottom Floor should be close to the Lowest Adjacent Grade, however the provided building elevations don't support that. Please double check that A7, C2.A and C2.F are all correct." |
A7. Building Diagram Number | Diagram # is 2B, Top of Bottom Floor (c2a) is above or equal to Lowest Adjacent Grade (c2f) | Error | "The Building Diagram type indicates that the structure should have a basement with the bottom floor below ground level, however the building elevations don't support that. Please double check that A7, C2.A and C2.F are all correct." |
A7. Building Diagram Number | Diagram # is 2B, there are values for c2a + c2b, and Top of Next Highest Floor (c2b) is less than 5.0' above Top of Bottom Floor (c2a) | Error | "The Building Diagram type indicates that the Top of Next Highest Floor should be greater than 5.0' above Top of Bottom Floor, however the provided building elevations don't support that. Please double check that A7, C2.A and C2.B are all correct." |
A7. Building Diagram Number | Diagram # is 3, Top of Bottom Floor (c2a) is below Lowest Adjacent Grade (c2f) | Error | "The Building Diagram type indicates that the structure should be a split-level with the bottom floor at or above ground level, however the provided building elevations don't support that. Please double check that A7, C2.A and C2.F are all correct." |
A7. Building Diagram Number | Diagram # is 3, Top of Bottom Floor (c2a) is more than 3.0' above Lowest Adjacent Grade (c2f) | Warning | "The Building Diagram type indicates that the structure's Top of Bottom Floor should be close to the Lowest Adjacent Grade, however the provided building elevations don't support that. Please double check that A7, C2.A and C2.F are all correct." |
A7. Building Diagram Number | Diagram # is 4, Top of Bottom Floor (c2a) is above or equal to Lowest Adjacent Grade (c2f) | Error | "The Building Diagram type indicates that the structure should have a basement with the bottom floor below ground level, however the building elevations don't support that. Please double check that A7, C2.A and C2.F are all correct." |
A7. Building Diagram Number | Diagram # is 5, Top of Bottom Floor (c2a) is below or equal to Lowest Adjacent Grade (c2f) | Error | "The Building Diagram type indicates that the structure should have an elevated floor with the bottom floor at or above ground level, however the provided building elevations don't support that. Please double check that A7, C2.A and C2.F are all correct." |
A7. Building Diagram Number | Diagram # is 5, there are values for c2a + c2b, and Top of Next Highest Floor (c2b) is less than 5.0' above Top of Bottom Floor (c2a) | Error | "The Building Diagram type indicates that the Top of Next Highest Floor should be greater than 5.0' above Top of Bottom Floor, however the provided building elevations don't support that. Please double check that A7, C2.A and C2.B are all correct." |
A7. Building Diagram Number | Diagram # is 6, Top of Bottom Floor (c2a) is below Lowest Adjacent Grade (c2f) | Error | "The Building Diagram type indicates that the structure should have an elevated floor with the bottom floor at or above ground level, however the provided building elevations don't support that. Please double check that A7, C2.A and C2.F are all correct." |
A7. Building Diagram Number | Diagram # is 6, Top of Bottom Floor (c2a) and Top of Next Highest Floor (c2b) should be filled out | Error | "The Building Diagram type indicates that the structure should have an elevated floor with an enclosure below, however the provided building elevations don't support that. Please double check that A7, C2.A and C2.B are all correct." |
A7. Building Diagram Number | Diagram # is 6, Top of Bottom Floor (c2a) is more than 7.0' above Lowest Adjacent Grade (c2f) | Warning | "The Building Diagram type indicates that the structure's Top of Bottom Floor should be close to the Lowest Adjacent Grade, however the provided building elevations don't support that. Please double check that A7, C2.A and C2.F are all correct." |
A7. Building Diagram Number | Diagram # is 7, Top of Bottom Floor (c2a) is below Lowest Adjacent Grade (c2f) | Error | "The Building Diagram type indicates that the structure should have an elevated floor with the bottom floor at or above ground level, however the provided building elevations don't support that. Please double check that A7, C2.A and C2.F are all correct." |
A7. Building Diagram Number | Diagram # is 7, Top of Bottom Floor (c2a) and Top of Next Highest Floor (c2b) should be filled out | Error | "The Building Diagram type indicates that the structure should have an elevated floor with an enclosure below, however the provided building elevations don't support that. Please double check that A7, C2.A and C2.B are all correct." |
A7. Building Diagram Number | Diagram # is 7, there are values for c2a + c2b, and Top of Next Highest Floor (c2b) is less than 5.0' above Top of Bottom Floor (c2a) | Error | "The Building Diagram type indicates that the Top of Next Highest Floor should be greater than 5.0' above Top of Bottom Floor, however the provided building elevations don't support that. Please double check that A7, C2.A and C2.B are all correct." |
A7. Building Diagram Number | Diagram # is 7, Top of Bottom Floor (c2a) is more than 7.0' above Lowest Adjacent Grade (c2f) | Warning | "The Building Diagram type indicates that the structure's Top of Bottom Floor should be close to the Lowest Adjacent Grade, however the provided building elevations don't support that. Please double check that A7, C2.A and C2.F are all correct." |
A7. Building Diagram Number | Diagram # is 8, Top of Bottom Floor (c2a) is below Lowest Adjacent Grade (c2f) | Error | "The Building Diagram type indicates that the structure should have an elevated floor with the bottom floor at or above ground level, however the provided building elevations don't support that. Please double check that A7, C2.A and C2.F are all correct." |
A7. Building Diagram Number | Diagram # is 8, Top of Bottom Floor (c2a) and Top of Next Highest Floor (c2b) should be filled out | Error | "The Building Diagram type indicates that the structure should have an elevated floor with an enclosure below, however the provided building elevations don't support that. Please double check that A7, C2.A and C2.B are all correct." |
A7. Building Diagram Number | Diagram # is 8, Top of Bottom Floor (c2a) is more than 7.0' above Lowest Adjacent Grade (c2f) | Warning | "The Building Diagram type indicates that the structure's Top of Bottom Floor should be close to the Lowest Adjacent Grade, however the provided building elevations don't support that. Please double check that A7, C2.A and C2.F are all correct." |
A7. Building Diagram Number | Diagram # is 9, Top of Bottom Floor (c2a) is above or equal to Lowest Adjacent Grade (c2f) | Error | "The Building Diagram type indicates that the structure should have a basement with the bottom floor below ground level, however the building elevations don't support that. Please double check that A7, C2.A and C2.F are all correct." |
A7. Building Diagram Number | Diagram # is 9, Top of Bottom Floor (c2a) and Top of Next Highest Floor (c2b) should be filled out | Error | "The Building Diagram type indicates that the structure should have an elevated floor with an enclosure below, however the provided building elevations don't support that. Please double check that A7, C2.A and C2.B are all correct." |
A7. Building Diagram Number | Diagram # is 9, there are values for c2a + c2b, and Top of Next Highest Floor (c2b) is more than 5.0' above Top of Bottom Floor (c2a) | Error | "The Building Diagram type indicates that the Top of Next Highest Floor should be less than 5.0' above Top of Bottom Floor, however the provided building elevations don't support that. Please double check that A7, C2.A and C2.B are all correct." |
C2 Values + Flood Zone + BFE
EC Field | Issue Trigger | Type | Issue Note |
B9. Base Flood Elevation | The Flood Zone is A, A1-20, AE, V, V1-20, VE, AH and the NFIP Lowest Floor Elevation is below Effective Base Flood Elevation | Error | "The Building's Lowest Floor is below the Effective Base Flood Elevation." |
B9. Base Flood Elevation | If the Flood Zone is A, A1-20, AE, V, V1-20, VE, AH and the NFIP Lowest Floor Elevation is below Effective Base Flood Elevation, Parcel has multiple zones | Error | "The Building's Lowest Floor is below the Effective Base Flood Elevation." |
B9. Base Flood Elevation | The Flood Zone is A, A1-20, AE, V, V1-20, VE, AH and the Regulatory Lowest Floor Elevation is below Local Design Flood Elevation | Warning | "The Building's Regulatory Lowest Floor is below your Local Design Flood Elevation (Regulatory BFE + Freeboard)." |
B9. Base Flood Elevation | If the Flood Zone is A, A1-20, AE, V, V1-20, VE, AH and the Regulatory Lowest Floor Elevation is below Local Design Flood Elevation, Parcel has multiple zones | Warning | "The Building's Regulatory Lowest Floor is below your Local Design Flood Elevation (Regulatory BFE + Freeboard)." |
B9. Base Flood Elevation | The Flood Zone is AO and the difference between the NFIP Lowest Floor Elevation & Highest adjacent grade is less than the Effective Base Flood Elevation | Error | "The difference between the building's Lowest Floor and the Highest adjacent grade is below the Effective BFE depth." |
B9. Base Flood Elevation | If the Flood Zone is AO and the difference between the NFIP Lowest Floor Elevation & Highest adjacent grade is less than the Effective Base Flood Elevation, Parcel has multiple zones | Error | "The difference between the building's Lowest Floor and the Highest adjacent grade is below the Effective BFE depth." |
B9. Base Flood Elevation | The Flood Zone is AO and the difference between the Regulatory Lowest Floor Elevation & Highest adjacent grade is less than the Local Design Flood Elevation | Warning | "The difference between the building's Lowest Floor and the Highest adjacent grade is below your Design Flood Elevation (Regulatory BFE depth + Freeboard)." |
B9. Base Flood Elevation | If the Flood Zone is AO and the difference between the Regulatory Lowest Floor Elevation & Highest adjacent grade is less than the Local Design Flood Elevation, Parcel has multiple zones | Warning | "The difference between the building's Lowest Floor and the Highest adjacent grade is belowyour Design Flood Elevation (Regulatory BFE depth + Freeboard)." |
B9. Base Flood Elevation | The Flood Zone is A, A1-20, AE, V, V1-20, VE, AH and the Lowest elevation of machinery is below the Effective Base Flood Elevation | Error | "The Building's Lowest elevation of machinery is below the Effective Base Flood Elevation." |
B9. Base Flood Elevation | If the Flood Zone is A, A1-20, AE, V, V1-20, VE, AH and the Lowest elevation of machinery is below the Effective Base Flood Elevation, Parcel has multiple zones | Error | "The Building's Lowest elevation of machinery is below the Effective Base Flood Elevation." |
B9. Base Flood Elevation | The Flood Zone is A, A1-20, AE, V, V1-20, VE, AH and the Lowest elevation of machinery is below Local Design Flood Elevation | Warning | "The Building's Lowest elevation of machinery is below your Design Flood Elevation (Regulatory BFE + Freeboard)." |
B9. Base Flood Elevation | If the Flood Zone is A, A1-20, AE, V, V1-20, VE, AH and the Lowest elevation of machinery is below Local Design Flood Elevation, Parcel has multiple zones | Warning | "The Building's Lowest elevation of machinery is below your Design Flood Elevation (Regulatory BFE + Freeboard)." |
B9. Base Flood Elevation | If the Flood Zone is AO and the difference between the Lowest elevation of machinery & Highest adjacent grade is less than the Effective Base Flood Elevation | Error | "The difference between the building's Lowest elevation of machinery and the Highest adjacent grade is below the Effective BFE depth." |
B9. Base Flood Elevation | If the Flood Zone is AO and the difference between the Lowest elevation of machinery & Highest adjacent grade is less than the Effective Base Flood Elevation, Parcel has multiple zones | Error | "The difference between the building's Lowest elevation of machinery and the Highest adjacent grade is below the Effective BFE depth." |
B9. Base Flood Elevation | If the Flood Zone is AO and the difference between the Lowest elevation of machinery & Highest adjacent grade is less than the Local Design Flood Elevation | Warning | "The difference between the building's Lowest elevation of machinery and the Highest adjacent grade is below your Local Design Flood Elevation (Regulatory BFE depth + Freeboard)." |
B9. Base Flood Elevation | If the Flood Zone is AO and the difference between the Lowest elevation of machinery & Highest adjacent grade is less than the Local Design Flood Elevation, Parcel has multiple zones | Warning | "The difference between the building's Lowest elevation of machinery and the Highest adjacent grade is below your Local Design Flood Elevation (Regulatory BFE depth + Freeboard)." |
|
Lowest adjacent grade is above BFE value | Warning | "Unless the Elevation Certificate being submitted is for LOMA or LOMR-F purposes, the Lowest Adjacent Grade is typically below the Effective Base Flood Elevation." |
Miscellaneous
EC Field
Issue Trigger
Type
Issue Note
Expiration Date
Expiration date is not 2022, Issue date is after Feb. 20, 2020
Error
"The Elevation Certificate version is out-of-date and therefore not valid."
EC Field | Issue Trigger | Type | Issue Note |
Expiration Date | Expiration date is not 2022, Issue date is after Feb. 20, 2020 | Error | "The Elevation Certificate version is out-of-date and therefore not valid." |